Need Help ?

Expert Answers

Description https://www.youtube.com/watch?v=KWJpKNQfXWo [+] Here is a simulato ...

Description https://www.youtube.com/watch?v=KWJpKNQfXWo [+] Here is a simulator (requires flash): http://introchem.chem.okstate.edu/DCICLA/iodine_clock.html. To use the simulator, you select your reactants, always totaling 100 mL in this case (instead of 20.0 mL in our experiment), click start, and then, when the solutions are all in the reaction beaker, click to start the timer. Watch for the color change to turn OFF the timer. You can see the times based on concentration of each reactant, as well as temperature, just like our data from lab. This is just a demo to show you what the lab work is like. We do not use any data from this simulator. The data we take in the lab is simply the time until we see the color change. The time is influenced strongly by consistent stirring and the timing of the stopwatch turning on/off. After you complete the pre-lab quiz online, you will get access to data to use in your notebook for the post-lab work. Here's a video overview of the lab: https://www.youtube.com/watch?v=li0jcKXrkfQ [+] You will make your own stock solution of sodium bisulfite and potassium iodate (Part I) and then use these stock solutions to create your reaction mixtures for trials #1 - 10. Do not make the solutions in Part I more than once. One solution will be made from a solid, the other will be made by diluting an aqueous solution. Weighing a solid: It's handy to fold the weigh paper into quarters so you can easily guide the solid into the flask. Your value does not have to match the expected value exactly-- just write the actual mass used. Take the weigh paper out of the balance when you add more solid so you will not spill chemicals inside the balance. Make sure you have at least 3 decimal place ("milligram" balance"). Work in pairs, and keep track of the two 10-mL cylinders to avoid contamination between solutions. Part II requires three trials of the same volumes of each stock solution. Note that the two solutions dilute each other when mixed, and you will calculate the new concentration of each reactant at the moment it is combined with the other solution. Use M1V1 = M2V2 and notice the final volume is the same for each trial. For every trial, combine the reactants and start the stopwatch at that exact moment. Write the time at which the color changes. Look for initial color change, whether it is a light color or a dark color. Part III requires the use of different volumes of each solution. Again, you will calculate the new, diluted concentration of each reactant at the moment it is mixed with the other solution. (What is the total volume now?) Don't forget to reflect proper significant figures in your measurements! Part IV requires repeating the initial volume combination at two additional temperatures. For the warmer temperature, keep your eyes on the solution-- it can change pretty fast! For the calculations on page 85, show a single calculation for a single trial with your lab report. The rest of the calculations may be shown in your notebook. https://wamaps3.s3.amazonaws.com/cfiles/23139/121_...

READ MORE >>

Description According to the ACE-Labs model (read Pages 3 and 4 of the laborato ...

Description According to the ACE-Labs model (read Pages 3 and 4 of the laboratory manual for details), this lab course aims to create research connections for the students that will bring them closer to understanding research as a social endeavor. We attempt to facilitate students’ understanding of the relevance of scientific research in modern society. For many, the very complex and rapid scientific and technological development of our society can be a black box. We may perceive the advances in medicine and materials, technological gadgets, etc. but do not really comprehend their origin and their connection with scientific research. In this assignment, you need to summarize an article (published in an accredited scientific journal) that is related to the experiment in this Module and submit a typed Word document. Your instructor will follow the rubric below to grade your assignment, but please refer to this PDF document: Post-lab Research Connection Assignment.pdf for more details of the rubric and some assignment tips. Rubric Criteria Ratings Pts This criterion is linked to a Learning OutcomeResearch Connection Assignment Q1Which specific topic or technique did you find in the article to be related to the experiment performed in this Module? 5 pts This criterion is linked to a Learning OutcomeResearch Connection Assignment Q2What research question(s) / objective(s) did the article address? 5 pts This criterion is linked to a Learning OutcomeResearch Connection Assignment Q3What procedure(s) did they utilize to answer their proposed research question(s) ? What results did they collect and how did they analyze them? 10 pts This criterion is linked to a Learning OutcomeResearch Connection Assignment Q4Did the researchers answer their question(s) or is further investigation needed? This is sometimes referred to as “future studies”? 5 pts This criterion is linked to a Learning OutcomeReferencesPlease follow the ACS (American Chemical Society) format and have both an in-text citation, as well as the full citation under the references heading. As a reminder, directly quoting an external source is unacceptable. You are required to paraphrase, in your own words, all cited information that appears in this assignment. Plagiarism is unacceptable! Any form of plagiarism will result in a “0” for this assignment or other relevant academic penalties, according to the Academic Integrity Policy in the syllabus. 5 pts Requirements: full length

READ MORE >>

Description Introduction to Spectroscopy Visible spectroscopy is the study of ...

Description Introduction to Spectroscopy Visible spectroscopy is the study of the interaction of radiation from the visible part of the electromagnetic spectrum with a chemical species. Understanding visible spectroscopy requires understanding visible light. Light travels in packets of energy called photons. Each photon has a specific energy related to a certain frequency or wavelength (E = h? = hc/?). Visible light consists of wavelengths ranging from roughly 400 nm (blue violet) to 700 nm (red). Absorption When all wavelengths of visible light are present, the light appears "white" to our eyes. If any wavelength is removed (absorbed), we perceive the remaining combination of wavelengths of light as the "complementary" color, the color across the color wheel (Figure 1). Figure 1: Color Wheel - Numbers are in ? (nm) Colored compounds, chromophores, are colored because of the absorption of visible radiation. The color is often a result of the compound absorbing a certain color of light, leading to the perception of the compound being the complementary color. For example, if white light passes through a test tube containing a solution of copper (II) sulfate (CuSO4), the solution will be blue because the Cu2+ ions strongly absorb “orange” photons of light (photons of light with ? ~ 600 nm). When a photon of colored light is absorbed by a chromophore (a colored compound) an electron transitions from lower energy orbital to higher energy orbital. The energy of absorbed radiation is equal to the energy difference (?E) between the highest energy electronic occupied orbital (OO) and an unoccupied orbital (UO). Many transition metal complexes and large conjugated organic molecules are brightly colored because this energy difference is equal to an energy within the visible region of the electromagnetic spectrum. Mathematically, this relationship is expressed by equation 1: Elight = h?light = hc/?light = ?E = EUO – EOO Before the absorption of a photon, the electrons within the compound are in the lowest energy orbitals possible. Such an electron configuration is called the ground state. The absorption of a photon of visible radiation by a compound promotes an electron from an occupied orbital to an unoccupied orbital. The result is a higher energy compound in an excited state. (Figure 2) Figure 2. Absorption of light resulting in the excitation of an electron The wavelength (i.e., frequency, energy, or color) of light required to promote an electron from the ground to the excited state is specific to each chemical, just as the energy difference between EOO and EUO is dependent on chemical identity. The goal of this experiment is to determine the concentration of FD&C Red Dye #40, a red chromophore, in red bottled sports drinks. Here is the structure of FD&C Red Dye #40 (molecular formula = C18H14N2Na2O8S2). You may need to refer to it during your experiment. The visible spectrum of FD&C Red Dye #40 is shown below. This type of spectrum is a plot of absorbance on the y-axis versus wavelength on the x-axis. The key thing to look for in a molecular absorption spectrum is the wavelength that best absorbs light, typically termed “?max”, which is short for “wavelength of maximum absorbance”. It is at this wavelength that the instrument can best detect changes in concentration. Notice that the spectrum indicates that the ?max for FD&C Red Dye #40 is at ~506 nm. Notice that 506 nm is in the "green" region of the visible light spectrum and is the complement to "red", which is the color of the dye. Figure 3: Absorbance spectrum of FD&C Red-Dye #40 Spectrophotometer Absorption and fluorescence are quantitatively measured by an instrument called a spectrometer. The spectrometer used in our lab contains absorption and excitation light sources, a cuvette holder, a diffraction grating to split light into different wavelengths, and a detector connected to a display (Figure 4). The solution to be analyzed is poured into a special vessel called a cuvette. A cuvette is a rectangular box with clear walls. The cuvette either holds the blank (typically, the solvent only) or the sample dissolved in the same solvent. Figure 4. From Vernier’s Website, Go Direct SpectroVis Plus Spectrophotometer To prevent spilling and insure a good measurement, fill a cuvette with a solution to about 75% of its total volume. Wipe the outside of a cuvette with a tissue before placing it in the sample holder. Beads of water, fingerprints, or bubbles in the solution interfere with the transmission of light through the sample. Gently insert a cuvette into the sample holder so the light passes through its clear walls. Mark a side of the cuvette at the very top and always insert the cuvette into the spectrometer the same way to avoid random fluctuations in the readings due to variations within the cuvette. Take care not to spill solutions into the spectrometer and replace scratched cuvettes. Figure 5: Plastic reusable cuvette with 1 cm pathlength. Click on the following link and watch how to insert the cuvette and read absorbance of samples in the Vernier Spectral Vis: https://www.youtube.com/watch?v=CEUa1JgKcp0#action=share Julia Schafer-Mar 01, 2021, 1:38 PM PST Procedure Ian Ball-Mar 01, 2021, 1:38 PM PST SAFETY FD&C Red Dye #40 is on the GRAS (“generally recognized as safe” by the FDA) list so it poses no safety threat. WASTE All solutions may be poured down the drains. It is just food coloring. PROCEDURE Equipment: Spectral Analysis (or other data-collection and analysis program) Vernier SpectroVis Plus (or compatible) Cuvette 25 mL, 50 mL & 100 mL volumetric flasks 5 mL, 10 mL, 15 mL & 20 mL volumetric pipets and bulbs Distilled water Pipet pump or pipet bulb Tissues (preferably lint-free) Work individually to measure your own unknown for this experiment. Note: Your instructor may have you work in groups to generate a rough standard curve of the FD&C Red Dye #40. Preparation of a Stock and Standard Solutions 1. Prepare a primary standard solution of FD&C Red Dye #40 by weighing out precisely 0.105 g of solid solute and quantitatively transferring it to a 500 mL volumetric flask. Next, a stock solution is prepared by making a 1:10 dilution of the primary standard solution – this is Standard #1. 2. From the stock solution, "Standard #1" of FD&C Red Dye #40, prepare four dilutions using water as the solvent: a) 5 to 25 mL; b) 10 to 25 mL; c) 15 to 25 mL, and d) 20 to 25 mL. These four solutions plus Standard #1 constitute your five standard solutions. Note: In the Prelab assignment you will have already calculated the concentration of FD&C Red Dye #40 in each of the standard solutions. Preparation of Unknown Sports Drink Sample 3. Obtain 25.00 mL of a sports drink sample to be compared to your standard curve. Your instructor will assign you a sports drink. Be sure to record the sample in your lab notebook. The goal is to use the absorbance of the unknown sample and the generated data from the standards to determine the amount of FD&C Red Dye #40 in the sample. Depending on the initial absorbance value of the sample, it may require dilution. Analysis of the Standards and Unknown on the Vernier SpectroVis Plus 4. Prepare a blank by filling an empty cuvette 3/4 full with distilled water. To correctly use a cuvette, remember: All cuvettes should be wiped clean and dry on the outside with a tissue. Handle cuvettes only by the top edge or the ribbed sides. All solutions should be free of bubbles. Always position the cuvette so the light passes through the clear sides. 5. Launch Spectral Analysis. Connect the SpectroVis Plus to your Chromebook or computer. Click or tap Absorbance vs. Concentration. 6. To calibrate the spectrometer, place the blank cuvette in the spectrometer and select Finish Calibration. Note: If necessary, wait for the spectrometer to warm up before selecting Finish Calibration. 7. Determine the optimal wavelength for creating the standard curve. a. Remove the blank cuvette, and place the highest concentration standard into the cuvette slot. b. The live graph will update with the spectrum of the sample. Click or tap the desired wavelength or enter the Wavelength. Click or tap Done. 8. You are now ready to collect absorbance-concentration data for the five standard solutions. Prepare a cuvette for each standard solution. To prepare a cuvette, rinse it twice with the standard solution and then fill it about 3/4 full. Repeat this with all five standards until you have the five cuvettes complete. To correctly use a cuvette, remember: All cuvettes should be wiped clean and dry on the outside with a tissue. Handle cuvettes only by the top edge or the ribbed sides. All solutions should be free of bubbles. Always position the cuvette so the light passes through the clear sides. You are now ready to collect absorbance-concentration data for the five standard solutions. a. Click or tap Collect to start data collection. b. Empty the stock solution from the cuvette. Using the 5:25 standard dilution, rinse the cuvette twice with ~1 mL amounts and then fill it 3/4 full. Wipe the outside with a tissue and place it in the device. c. When the value has stabilized, click or tap Keep and enter the concentration of the standard in units of Molarity (mol/L). Click or tap Keep Point. The absorbance and concentration values have now been saved for the first solution. d. Discard the cuvette contents as directed by the safety guidelines. Using the 10:25 standard solution, rinse the cuvette twice with ~1 mL amounts, and then fill it 3/4 full. Place the cuvette in the device, wait for the value displayed on the screen to stabilize, and click or tap Keep. Enter the concentration of the standard in units of Molarity (mol/L). Click or tap Keep Point. e. Repeat the procedure for the 15:25 and 20:20 dilutions standards. Note: Wait until Step 10 to test the unknown. f. Click or tap Stop to stop data collection. Preparation of Standard Curve 9. Display a graph of absorbance vs. concentration with a linear regression curve. a. Download and open the data file (.smbl file) prepared for the class in Vernier Spectral Analysis. b. Edit the concentration column to reflect the actual molarities used in the experiment. c. Click or tap Graph Tools, , and choose Edit Graph Options. d. Enter 0 as the value for both the Left value for the x-axis and the Bottom value for the y-axis. Dismiss the Graph Options box. e. Click or tap Graph Tools, , and choose Apply Curve Fit. f. Select Linear as the curve fit and Dismiss the Curve Fit box. The linear-regression statistics for these two data columns are displayed for the equation in the form: y = mx + b where x is concentration, y is absorbance, m is the slope, and b is the y-intercept. Note: One indicator of the quality of your data is the size of b. It is a very small value if the regression line passes through or near the origin. The correlation coefficient, r, indicates how closely the data points match up with (or fit) the regression line. A value of 1.00 indicates a nearly perfect fit. The graph should indicate a direct relationship between absorbance and concentration, a relationship known as Beer’s law. The regression line should closely fit the five data points and pass-through (or near) the origin of the graph. Measure the Absorbance of the Unknown 10. Determine the absorbance value of the unknown sports drink solution. a. Obtain a new cuvette. Rinse the cuvette twice with the unknown solution and fill it about 3/4 full. Wipe the outside of the cuvette and place it into the device. b. Monitor the absorbance value. When this value has stabilized, record it. c. If the sample is outside the range of the calibration standards, you will need to quantitatively dilute the sample and re-analyze it. Calculations Using the absorbance of your unknown sample, determine the concentration of FD&C Red Dye #40 in the sample measured. Taking into account any dilutions and using the serving size on the container, calculate how many grams of FD&C Red Dye #40 per serving of your unknown sports drink. POST-EXPERIMENT DISCUSSION QUESTIONS – Answer these questions in your Conclusion as directed by your instructor 1. If we had blue dye, red dye, and yellow dye in the samples. How could we focus on just the red dye’s concentration? 2. What is the wavelength setting on the spectrophotometer for this experiment? Why does the instrument need to be set at this wavelength? 3. Why did we need to prepare and analyze a set of standards? 4. What is Beer’s Law? Was Beer’s Law used in this experiment? If so, how? If so, why could we use it? 5. Of what, exactly, are we measuring the absorbance? Be specific. 6. Discuss any error(s) that may have been introduced in the analysis of the red dye.

READ MORE >>

Description Hi, I need help with my chemistry assignment. Please follow the lab ...

Description Hi, I need help with my chemistry assignment. Please follow the lab format and organize all work in order. Please make sure you attach the graph in the lab as well. Read all of the lab instructions pdf and follow it carefully. I will also send you more links that might be helpful to solve.

READ MORE >>

Description A lab report on Acid-Base titration. Some parts of the report are a ...

Description A lab report on Acid-Base titration. Some parts of the report are already completed. (All the dataset are already collected and the titration curves are already done). Only the calculations and the other questions are left to do.

READ MORE >>

Description Check out the attached documents. The lab document is attached.The ...

Description Check out the attached documents. The lab document is attached.The pictures for the experiment is also attached. Please read them carefully. This is an informal lab report for Experiment 3 Qualitative Analysis of Electrolysis Reactions.Please write neatly and legibly. Part A: Preliminary observations Table 1: Tests for Cu2+ and SO3-2 What I Did Observations including before & after colors Positive test for Cu2+: 0.020 M CuSO4 + conc. NH3 Negative test for Cu2+: Distilled water + conc. NH3 Positive test for sulfite, SO3-2:0.1 M Na2SO3 + 0.2 mM KMnO4 Negative test for sulfite, SO3-2:Distilled water + 0.2 mM KMnO4 Part B: Qualitative Analysis of an Electrolytic Cell (Cu and Zn electrodes) Table 2: Observations and measurements What I Did What I observed or measured Conclusion(s) based on observation(s) or measurement(s) Observed Cu cathode Observed solution near Cu cathode Sulfite (SO32-) test Massed Zn anode before experiment (g) Massed Zn anode after experiment (g) Observed Zn anode Observed solution near Zn anode Question 1: Identify which of the reduction half-reactions (1A, 1B, 1C) occurs at the cathode.Your explanation is in the conclusion column of Table 2, so no need to defend answer. ____________ Question 2: Explain why the reduction of Zn (s) was not included as a choice. Think electron configuration. Question 3: Explain why the reduction of Cu (s) was not included as a choice. Think electron configuration. Question 4: Identify which of the oxidation half-reactions (2A or 2B) occurs at the anode. Your explanation is in the conclusion column of Table 2, so no need to defend your answer. ____________ Question 5: Explain why the oxidation of Zn2+ (aq) was not included as a choice. Think electron configuration. Question 6: Explain why the oxidation of SO42- (aq) was not included as a choice. (Hint: Draw the Lewis structure of SO42- to determine the oxidation number of the sulfur atom) Part C: Qualitative Analysis of an Electrolytic Cell (two Cu electrodes) Table 3: Observations What I Did What I observed Conclusion(s) based on observation(s) Observed color of solution before expt. Observed color of solution after expt. Observed Cu anode (“right” in diagram) Observed solution near Cu anode (“right” in diagram) Observed Cu cathode (“left” in diagram) Observed solution near Cu cathode (“left” in diagram) Flame test Cu2+ test Sulfite(SO32-) test undefined Question 7: Identify which of the oxidation half-reactions (3A or 3B) occurs at the anode.Your explanation is in the conclusion column of Table 3, so no need to defend your answer. ____________ undefined undefined Question 8: Identify which of the reduction half-reactions (4A or 4B) occurs at the cathode.Your explanation is in the conclusion column of Table 3, so no need to defend your answer. __________ undefined undefined undefined undefined Question 9a. Using the half-reactions in your answers to questions 1 & 4, write the net cell reaction for the Zn-Cu electrolytic cell. Show both half-reactions and the net call reaction in your answer. Be sure the # of electrons are the same in the 2 half-reactions before adding them. undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined Question 9b. Using the half-reactions in your answers to questions 7 and 8, write the net cell reaction for the Cu-H+ electrolytic cell. Show both half-reactions and the net call reaction in your answer. Be sure the # of electrons are the same in the 2 half-reactions before adding them.

READ MORE >>

Description Module 05 Lab 02 - Unknown Strong Acid Lab/Questions and Concept Te ...

Description Module 05 Lab 02 - Unknown Strong Acid Lab/Questions and Concept Test Instructions for Virtual Lab: Record all observations and take screenshots of your work. Go to lab page: http://chemcollective.org/acid-base Strong Acid Determine the concentration of the unknown strong acid 3 lab questions dealing with the Acid Lab (below) Briefly describe the equivalence point in a titration. What species are present? Phenolphthalein is an indicator that will change color at pH close to 8. Why would we use phenolphthalein to determine when the equivalence point is reached? At what point do you know that you have added enough base from the buret into the acid solution? What happens to your calculations for the concentration of the acid if you accidentally add in more base than you need to? Concept test (note: you will need to record the answers separately) Click on the words "Unknown Acid Problem" (on the right side just above Work Bench 1), which will further explain the lab problem within this assignment. The lab will center on: Determining the concentration of the acid (showing math steps and auto graded answer) 3 lab questions Concept test Submit a zip file of all screenshots and answers for this lab activity. For assistance taking a screenshot, refer to the following guide. For assistance zipping files together, refer to the following guide.

READ MORE >>

Description B. Calculations: Determine the mass of iron consumed in the reacti ...

Description B. Calculations: Determine the mass of iron consumed in the reaction. Show your work. (4 pts) Formula: 2.Calculate the number of moles of iron consumed using dimensional analysis and the molar mass of iron as a conversion factor. Show your work. (10 pts) 3. Determine the mass of copper formed. Show your work. (4 pts) Formula: 4. Calculate the number of moles of copper formed using dimensional analysis and the molar mass of copper as a conversion factor. Show your work. (10 pts) 5. What is the experimental mole ratio between the iron and the copper? Determine the simplest whole number ratio of moles of iron consumed (see Question 2), to moles of copper formed (see Question 4). [Note: To find the ratio, you must use your answers to Question 2 and Question 4 and divide both values by whatever value is smaller.] (8 pts) C. Analysis Questions: 6. What color was the 1M CuCl22H20 solution before the nails were placed in it? What ion was responsible for this color? Explain your reasoning with support from the lab. (8 pts) 7. After the nails were allowed to react, did the solution change color? What was responsible for this color change? Explain your reasoning with support from the lab. (8 pts) 8. What type of chemical reaction was this? You need to determine the type of reaction and explain how you know it falls into that category. (8 pts) 9. What was the solid product that formed on the nails? Explain your reasoning with support from the lab. (8 pts) 10. Based on the experimental mole ratio, which of the following equations is MOST LIKELY to be the one represented by this experiment? Justify your answer with support from the lab. (9 pts) 11. Why is knowing the “mole ratio” essential when performing stoichiometric calculations? Your response must include (a) a discussion of balanced equations in the context of the law of conservation of mass (8 pts) and (b) an example different from the one in this lab that shows how a mole ratio is used in a stoichiometric calculation (9 pts).

READ MORE >>

Description Experimental Design and Scientific Method Activity. Instructions an ...

Description Experimental Design and Scientific Method Activity. Instructions and requirements are attached.

READ MORE >>

Description Module 04 Lab 02 - Bioremediation of Oil Spills To access your lab ...

Description Module 04 Lab 02 - Bioremediation of Oil Spills To access your lab, please follow these instructions-- *if you have already done steps 1-10, simply log in to view your course and participate in lab activities: Please go to: https://oli.cmu.edu/jcourse/webui/register/student.do This will bring you to the “Course Key Students” page. Enter the Course Key "mangan-f20" in the box and click "register.” Create an account by filling in the information (be sure to use an account ID and password you will remember and make a note of it for future logins). Click “I’m not a robot” and “Sign Up.” Confirm your account by clicking on “confirm account.” Read the consent form, then agree by choosing “I agree” and “submit.” Click on “Register” for the Chemistry Virtual Lab Activities with Instructor Manganiello. Click on “Enter course” next to the red arrow to begin the lab. Find the lab required for the assignment and begin work. Should you experience issues, please contact the PSC at 1-866-693-2211 and let them know you need assistance with labs in the CHM1100 course. Purposes of Experiment: To determine the relationship between various molecules and determine how to add limiting reagents based on the needed reaction. Unit 3: Bioremediation: Module 7: Chemical Reactions and Module 8: Bioremediation Accelerations Total: 30 Points A Total of +15 (or more) Correct screenshots will be required (where you enter your answer and they tell you that you are correct). Screenshots should be of the entire webpage, including your name and the page number. If a page must be captured in multiple screenshots, label the images as part 1, part 2, etc. You will step through this lab completing different tasks on different pages. At the end of each task, you will see a "Correct" or "Incorrect" screen. You are able to try again if you see an "Incorrect" screen. Be sure to take a screenshot of each "Correct" screen. Submit a zip file of all screenshots for this lab activity.

READ MORE >>
QUICK ORDER

Place a Quick Order

Our verified writers got you covered. Let us help you balance between studies, work, and family.

We provide our assistance to the numerous clients looking for a professional writing service.

Order Now
Designed and developed by Brian Mubichi (mubix)
WhatsApp